Toro Micro-Master® 4500 Series Controllers


The Micro-Master 4500 Series controller is used for horticultural and agricultural applications with Filter Flushing and Chemical Fertiliser Injection Programs

Load and save facility for 7 complete file programs (i.e. Prog. A; Prog. B; Injection; Filter etc.)
Allows for easy seasonal recall Programming

Station watering options 0-9999 seconds, 1 sec. increments 0-9999 minutes, 1 min. increments 0-9999 volume units, 1 unit increments

Load and save facility for 7 complete file programs (i.e. Prog. A; Prog. B; Injection; Filter etc.)
Allows for easy seasonal recall

Auto Skip Facility: A1: 0-250 secs at irrigation start to allow system to stabilize A2: Operational Scanning time/frequency (0-250 secs)

In group mode, the seven terminals allotted to chemical injection and filter flush can be used for irrigation valves if chemical injection/filter flush not used Operation

Fault Reporting Monitors flow or pressure switches connected to the ASKIP terminal and utilises the auto skip programmable delay times Memory

9 volt Alkaline battery (included) keeps correct time during power failure (150 hours nomimal) Power Sources

Extensive Protection against field and mains power surges
Relay outputs to field valves ensures reliable operation under the most severe conditions

Isolated logic board protected by additional transformer which diverts surges to earth Communications/Software
Input power | 240 volt 50 Hz, single phase or 12 volt DC |
Operating limits | 210 VAC to 265 VAC or 11 VDC to 16 VDC |
Quiescent 12 V input power | 15 mA at 12 VDC (55 mA with one output relay and pump start relay active), total current = solenoid current + 70 mA |
Output power | |
Total station capacity | 24 VAC at 2.0 A max. or 12 VDC at 2.0 A max |
Superior lightning and surge protection | |
Transformer primary | 275V, 2,500 amp/20 micro sec. Surge protection, A-E, N, E. Transformer secondary, 24 VAC, 6,500 amp/20 micro sec. Field wiring (32 stations and pump start), 6,500 amp/20 micro sec Large valve wiring terminals, detachable, do not need to remove valve wires for servicing Relay outputs to field valves ensures reliable operation in the most rugged conditions Permanent program memory maintains all saved programs if power fails. No standby battery is required 9 volt Alkaline battery (included) keeps correct time during power failure (150 hours nominal) Operating Conditions |
Dimensions |
|
Temperature | -10°C to 65°C |
Download | Type | Information |
---|---|---|
Detailed Specifications | Specifications |