Suitable for connection of up to 3 x 0.5-1.0 mm2, 2 x 1.5-2.5mm2 copper cables. Important: Must be used with sealant gel (Ordering information 1012592) to avoid corrosion of copper cables.
Bare each cable back 12 mm. Twist cables together and slip through crimping ring. Crimp the ring securely onto the combined cables. Fill the connector completely with sealant before pushing the cap on and snapping closed. Sealant should ooze out through holes around the wires and copper. Ensure that no copper cable is exposed and the connection is secure.